Category:Mining Machine Cyanidation Equipment
Product Introduction:The desorption and electrolysis complete set of equipment is a key part of the gold extraction process using the fluoride-carbon slurry method. It’s an all-in-one setup made up of an electric heater, desorption column, heat exchanger, gold electrolytic tank, pumps, and other components. It’s compact, easy to install, with a desorption rate of over 96% and an electrolysis rate greater than 99%.
| Model | Applicable scale | System Device Details | System Instrument Details | Operating Parameters | |
| Mine scale (t/d) | Raw ore grade (g/t) | ||||
| GKJD-200 | <150 | 2-8 | JXZ Desorption Column GLQ Filter DJC Electrolytic Cell CQ Circulation Pump DRQ Electric Heater W Air Compressor PYC Desorption Liquid Tank XL Control Cabinet GDF Rectifier Cabinet | Remote resistance diaphragm pressure gauge Pressure indicating controller Diaphragm pressure gauge Vortex flowmeter Flow totalizer Thermal temperature gauge Temperature sensor Level gauge Temperature indicating controller | Temperature: 150 ± 2°C pH: ≥13.5 Flow rate: 2.4 m³/h Current: 300 ± 100 A Electrolysis voltage: 2-4 V Installed power: 75.6 kW Desorption tank pressure: 0.5-0.57 MPa Electrolytic tank pressure: 0.45-0.52 MPa |
| GKJD-300 | 150-300 | ||||
| GKJD-500 | 300-500 | ||||
| GKJD-700 | 500-750 | ||||
| GKJD-900 | 750-1000 | ||||
| GKJD-1000 | 1000-1500 | ||||
| GKJD-1200 | 1000-1500 | ||||
| GKJD-1500 | >1500 | ||||